Features:
*Automated gain¡¢Peak Hold and Peak Memory£»
*Automated display precise flaw location(Depth d¡¢level p¡¢distance s¡¢amplitude¡¢sz dB¡¢§æ)£»
*Ten independence setup, any criterion can be input freely, we can work in the scene without test block£»
*Big memory of 300 A graph and 30000 thickness value.
*Gate and DAC alarm£»Acoustic-Optical alarm;
*RS232 port£¬communication with pc is easy£»
*The embeded software can be online updated£»
*Li battery, continue working time up to 7 hours;
*Other assistant function;
*Display freeze;
*Automated echo degree;
*Angles and K-value;
*Lock and unlock function of system parameters;
*Dormancy and screen savers;
*Electronic clock calendar ;
*Two gates setting and alarm indication;
*High-speed capture and very low noise;
*DAC¡¢AVG; Solid metal housing (IP65);
*Provides high contrast viewing of the waveform from bright, direct sunlight to completae darkness and easy to read from all angles;
*Powerful pc software and reports can be export to excel;
Specifications:
Designation |
Technical Data |
Range of scanning (mm) |
Range of scanning (mm)£º2.5¡«60000(Steel Longitudinal wave) Steps: 2.5,5,10,20, 30,40,50,60,70,80,90, 100,150,200, 250, 300, 350, 400, 450,500,600,700,800,900,1000,2000,3000,4000,5000,6000 Adjusting step: 0.1mm£¨2.5 mm¡«99.9mm£©£¬1mm£¨100mm¡«10000mm£© |
D-delay (ms) |
D-delay (ms)£º-20¡«+3400
Steps: -20,-10,0.0, 10, 20, 50,100,150,200,250,300,350,400,450,500, 600,
700,800,900,1000,1500,2000,2500,3000,3400.
Adjusting steps: 0.1£¨-20ms¡«999.9ms£©£¬1£¨1000ms¡«3400ms£© |
P-delay (ms) |
P-delay£º0.0¡«99.99
Adjusting steps: 0.01 |
MTLVEL£¨m/s£© |
MTLVEL£º1000¡«9999
7 fixed levels: 2260,2730,3080,3230,4700,5920,6300
Adjusting steps:1 |
Working mode |
Single probe (receiving and sending), double probe (one for receiving and another for sending), transmission(transmission probe) |
FrequencyRange (MHz) |
0.4¨C20 |
Gain adjustment (dB) |
0¡«110
Adjusting step: 0.0£¬0.2£¬0.5£¬1£¬2£¬6£¬12 |
Reject |
0%¡«80% of screen height, step: 1% |
Vertical linear error |
Vertical linear error is not more than 3% |
Horizontal linear error |
Not more than 0.2% in the scanning range |
Sensitivity Leavings |
¡Ý62 dB |
Dynamic range |
¡Ý32dB |
Alarm |
Three modes, i.e. forbidden wave, loss wave and auto |
Monitoring door |
2, expressed by bold transverse line, whose start, width and height are adjustable.
Adjusting range of start (mm): horizontal pixel 0~208, the displayed value is relative with the scanning range.
Step: value in mm corresponding to a pixel (relative with the scanning range)
Adjusting range of width (mm): horizontal pixel 4¡«212, the displayed value is relative with the scanning range.
Step: value in mm corresponding to a pixel (relative with the scanning range)
Adjusting range of height: 2%~90% of vertical graduation
Step graduation: 1% |
Display |
Display: high-brightness lattice |
A-Scan display area |
Full screen or local
A-Scan display freezing and de-freezingA-Scan filling |
Data save |
300 A-Scan images (including setting of instrument)
30000 values of thickness (300 sets) |
Standard interface |
RS232 for communication with PC |
Measuring unit |
mm/inch |
Battery |
Li battery 4¡Á3.6V4800mAh |
Power adaptor |
Input 100V¡«240V/50Hz¡«60Hz
Output 9V¡«12VDC/1.5A |
Working temperature |
-20¡æ¡«70¡æ |
Working humidity |
20%¡«90% |
Port type |
BNC |
Dimension (mm) |
240¡Á180¡Á50 |
Weight (kg) |
1.8 | |